SU60 Technical Information
|
Application |
Interrupted Uninterrupted |
|
|
Thermal Current Rating |
100A |
100A |
|
Intermittent Current Rating: |
||
|
30% Duty |
185A |
185A |
|
40% Duty |
160A |
160A |
|
50% Duty |
140A |
140A |
|
60% Duty |
130A |
130A |
|
70% Duty |
120A |
120A |
|
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant:(In accordance with UL583*) |
||
|
Blowouts |
500A at 96V D.C. |
|
|
No Blowouts |
500A at 48V D.C. |
|
|
Rated Fault Current Breaking Capacity (Icn) Resistive Load:(In accordance with UL508*) |
||
|
Blowouts |
150A at 96V D.C. |
|
|
No Blowouts |
150A at 48V D.C. |
|
|
Maximum Recommended Contact Voltages |
||
|
Blowouts |
96V |
96V |
|
No Blowouts |
48V |
48V |
|
Typical Voltage Drop per pole across New Contacts at 100A |
50mV |
|
|
|
||
|
Mechanical Durability |
> 3,000,000 Cycles |
|
|
Coil Voltage Available (Us) (Rectifier board required for A.C.) |
6 - 130V |
|